COMPRESSOR WARRANTY POLICY
COMPRESSOR WARRANTY POLICY
All AP Air compressors are warranted to be free from defective materials and/or
workmanship for the period specified - from date of purchase.
COMPRESSORS 1-YEAR
*An original copy of work order showing the following steps were taken when installing
compressor must be provided before warranty will be considered.
FAILURE TO PROVIDE WORK ORDER OR FOLLOW THESE 8 STEPS WHEN INSTALLING
COMPRESSOR WILL VOID WARRANTY.
1. CHECK COMPRESSOR PRIOR TO INSTALLATION FOR AIR GAP IN CLUTCH.
2. CHECK COMPRESSOR FOR PROPER OIL AMOUNT PER OEM OR
MANUFACTURERS RECOMMENDATION.
3. MUST FLUSH A/C SYSTEM WITH PROPER FLUSH AND FLUSHING METHOD
4. MUST REPLACE FILTER DRIER OR ACCUMULATOR
5. MUST REPLACE EXPANSION VALVE OR ORIFICE TUBE
6. CHECK FOR PROPER AIRFLOW THROUGH COOLING FINS OF CONDENSER AND RADIATOR.
REPLACE IF NEEDED.
7. EVACUATE SYSTEM TO DEEP VACUUM, 29.95 In.-HG, INCHES OF VACUUM
8. CHECK FOR CORRECT GAS CHARGE
No labor or refrigerant allowance will be allowed for losses involved in the installation or reinstallation of the
compressor. During the warranty period, parts determined to be covered will be repaired or replaced
at our discretion. Approved warranties are non-refundable and will be in the form of merchandise credit or refund. All
warranties of compressors are to the original owner/purchaser only; a transfer of ownership or any 3rd party
installation will terminate the warranty. All compressors are to be installed by an authorized dealer or repair
technician. This warranty does not cover defects caused by customer neglect, incorrect application, wiring,
alteration or repairs made outside the company’s authorization.